According to the special equipment safety law and the safety technology supervision regulations for fixed pressure vessels (TSG 21-2016), judge whether nitrogen storage tanks need to be inspected, the key lies in whether it meets the legal definition of “pressure vessel.
I. Judgment basis
pressure vessels must meet the following three conditions at the same time to be included in the supervision:
- working pressure ≥ 0.1MPa(Gauge pressure);
- volume ≥ 30L(That is, 0. 03m³);
- the medium is gas, liquefied gas or liquid whose maximum operating temperature is greater than or equal to the standard boiling point.
The nitrogen storage tank you mentioned: volume 2m³ (much larger than 30L), working pressure 0. 84MPa (> 0.1MPa), the medium is nitrogen (permanent gas), which completely meets all the above conditions, sofixed Pressure Vessels belonging to special equipment must be registered for use according to law and subject to regular inspection..
II. Inspection requirements
before putting it into use, you must submit design documents, manufacturing materials, installation supervision and inspection certificates, etc. to the local market supervision and management department (former quality supervision bureau) to applyuse Registration; During operation, regular inspection shall be conducted periodically (generally, the first inspection is within 3 years after being put into use, and once every 3-6 years later, depending on the medium and risk level).
Note: Even if nitrogen is inert gas, non-toxic and harmless, it is not exempt from supervision-regulations focus on the potential energy risk caused by physical parameters (pressure × volume), rather than chemical hazards.